You searched for: Sterilization Indicators
Changing appearances in color or pattern, the sterilization indicators visually show if cleaning conditions are passing or procedures have been completed. Eliminating any confusion or possibility instruments will not be sterile, indicators are used routinely in clinical and research environments where contamination elimination is crucial. With the temperature resistance required to endure the purification, the sterilization indicators are available in different forms such as tapes, ampoules, and sticks.
Bionova® Spore Strips for Steam and LTSF (10⁶ Spores)
Supplier: TERRAGENE
Spore strips biological indicator for steam and formaldehyde sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10⁶ spores per strip. It is suggested the use of Bionova® MC1020-2 culture medium. Read out after 24 hours for Steam, or 48 hours for formaldehyde.
Expand 1 Items
Bionova® Spore Strips for Ethylene Oxide and Dry heat (10⁶ Spores)
Supplier: TERRAGENE
Spore strips biological indicator for ethylene oxide and dry heat sterilization processes. Bacillus atrophaeus (ATCC 9372) 10⁶ spores per strip. Bacillus atrophaeus (ATCC 9372) 10⁶ esporas per coupon. Readout time 48 hours. It is suggested the use of Bionova® MC1020-2 culture medium.
Expand 1 Items
Bionova® 2 h Biological Indicator for LTSF
Supplier: TERRAGENE
Rapid self-contained biological indicator for formaldehyde sterilization processes. Geobacillus stearothermophilus (ATCC® 7953) 10⁶ spores per vial. Readout: 2 hours.
Expand 1 Items
Bionova® 3 h Biological Indicator for Steam (FDA)
Supplier: TERRAGENE
Rapid self-contained biological indicator for steam sterilization processes. Geobacillus stearothermophilus (ATCC® 7953) 10⁶ spores per vial. Readout: 3 hours.
Expand 1 Items
Chemdye® Self-Adhesive Label Indicator for Hydrogen Peroxide
Supplier: TERRAGENE
Automatic record system. chemical indicator, double self-adhesive labels printed with indicator ink (29×22.5 mm), for plasma or vaporized hydrogen peroxide sterilization processes. Rolls of 750 labels. Turns from purple to green.
Expand 1 Items
Bionova® 48 h Biological Indicator for LTSF
Supplier: TERRAGENE
Self-contained biological indicator for formaldehyde sterilization processes. Geobacillus stearothermophilus (ATCC® 7953) 10⁶ spores per vial. Readout: 48 hours.
Expand 1 Items
Bionova® 4 h Biological Indicator for Ethylene Oxide
Supplier: TERRAGENE
Rapid self-contained biological indicator for ethylene oxide sterilization processes. Bacillus atrophaeus (ATCC® 9372) 10⁶ spores per vial. Readout: 4 hours.
Expand 1 Items
Vapor Line® Type 5 Integrator, Propper
Supplier: Propper
Vapor Line® integrators monitor all the critical parameters of steam sterilization.
Expand 3 Items
Chemdye® Bowie-Dick Test Card Kit for Steam (FDA)
Supplier: TERRAGENE
Bowie - Dick test card kit for Steam sterilization processes, includes Bowie - Dick-test card chemical indicators and holder. 1 holder+120 test cards.
Expand 1 Items
Hi Temperature Indicator Tape, Electron Microscopy Sciences
Supplier: Electron Microscopy Sciences
Specialty cloth-textured Hi Temperature Indicator tape shows the word “STERILIZED” in bold, black letters after standard sterilization processing. The tape sticks to almost any surface or shape, holds fast in 550°F dry oven temperatures. Available in widths of 1/2", 3/4", and 1" on 250” rolls.
Expand 3 Items
Bionova® Spore Strips for Dry Heat, Steam and Ethylene Oxide
Supplier: TERRAGENE
Spore strips biological indicator for steam, ethylene oxide and dry heat sterilization processes. Geobacillus stearothermophilus (ATCC® 7953) 10⁶ and Bacillus atrophaeus (ATCC® 9372) 10⁶ spores per strip. Readout time 24/48 hours. It is suggested the use of Bionova® MC1020-2 culture medium.
Expand 1 Items
Bionova® 48 h Biological Indicator for Dry Heat
Supplier: TERRAGENE
Semi self-contained biological indicator for dry heat sterilization processes. Bacillus atrophaeus (ATCC 9372) 10⁶ spores per vial. Each box of 50 tubes. Readout: 48 hours. 25A+25B/BX.
Expand 1 Items
Once-A-Day® Bowie Dick Test Pak, Propper Manufacturing
Supplier: Propper
Once-A-Day Test Pak® is a pre-assembled disposable Bowie and Dick test for daily monitoring of pre-vacuum sterilizers at 270 to 276 °F.
Expand 1 Items
Bionova® MiniPro Auto-Reader
Supplier: TERRAGENE
Auto-reader Incubator for hygiene monitoring system with 3 positions for incubation and transmittance readout of protein pens. Built-in printer.
Expand 1 Items
Comply™ Chemical Integrators, 3M™
Supplier: Healthcare Products
Comply™ Chemical Integrators provides an immediate, accurate, and easy-to-read method of monitoring sterilization process conditions inside each pack.
Expand 3 Items
Bionova® Spore coupon for Hydrogen Peroxide (10⁶ spores)
Supplier: TERRAGENE
Spore coupon biological indicator for plasma or vaporized hydrogen peroxide in single glassine packaging. Geobacillus stearothermophilus (ATCC 7953) 10⁶ spores per coupon. Readout in 24 h. It is suggested the use of Bionova® MC1020-2 culture medium.
Expand 1 Items
Attest™ Rapid 5 Steam Plus Test Pack, 3M™
Supplier: Healthcare Products
Fast, easy to use steam test packs contain a three hour Attest™ Rapid Readout Biological Indicator (BI) plus a moving front (SteriGage™) Class 5 Integrating Indicator.
Expand 2 Items
Attest™ Biological Indicators for EO, 3M™
Supplier: Healthcare Products
3M™ Attest™ self-contained BI is designed for monitoring ethylene oxide (EO) sterilization processes.
Expand 1 Items
VERIFY™ Steam Integrator Strips, Steris
Supplier: Steris
Chemical integrators monitor all critical parameters of steam sterilization (time, temperature and steam quality).
Expand 2 Items
Dart® Daily Air Removal Test Pack, Steris
Supplier: Steris
The Dart® daily air removal test is a pre-assembled Bowie-Dick test pack products used in monitoring healthcare steam sterilizers.
Expand 2 Items
Bionova® Dual Incubator for Biological IndicaD23:D35
Supplier: TERRAGENE
Dual biological indicator Incubator. 37±2 or 60±2 °C.
Expand 1 Items
Chemdye® PRO1 ALERT Hygiene Monitoring System
Supplier: TERRAGENE
Quantitative protein detection system. Designed to detect and quantify proteins from allergenic food with high sensitivity on surfaces and difficult to access areas after the cleaning process. Need to use MINI PRO reader.
Expand 1 Items
STERIL-PEEL™ Self-Seal Sterilization Rolls, GS Medical Packaging
Supplier: GS Medical Packaging
All STERIL-PEEL™ products are manufactured from medical grade bleached kraft paper
Expand 6 Items
STERIL-PEEL™ Heat Seal Pouches, GS Medical Packaging
Supplier: GS Medical Packaging
All STERIL-PEEL™ products are manufactured from medical grade bleached kraft paper
Expand 1 Items
Bionova® Self-Contained Spore Ampoules for Steam (10⁶ Spores/0,6 ml)
Supplier: TERRAGENE
Self-contained spore ampoules for monitoring industrial steam low temperature 110 to 121 °C sterilization of liquids. Bacillus subtilis DSM 5230 (ATCC 35021) 10⁶ spores per ampoule. (7×40 mm). 0,6 ml of culture medium. 200(+)+20(-)/BX.
Expand 1 Items
Comply™ Thermalog Steam Chemical Integrator, 3M™
Supplier: Healthcare Products
Class 5 steam chemical integrators can be used in all 250 to 275 °F steam sterilization cycles.
Expand 1 Items
Integron® Chemical Integrator for Steam (FDA)
Supplier: TERRAGENE
Moving front chemical integrator to monitor Steam sterilization processes between 118 and 138 °C. ISO 11140-1 Type 5.
Expand 1 Items
Comply™ Bowie-Dick Plus Test Packs, 3M™
Supplier: Healthcare Products
Comply™ Bowie-Dick test packs are used to monitor the performance of vacuum-assisted 132 to 134 °C (270 to 273 °F) steam sterilizers.
Expand 2 Items
Steraffirm™ Bowie-Dick Test Pack, STERIS®
Supplier: Steris
Test packs consist of preassembled single-use test packs designed to evaluate the performance of the air removal system of a pre-vacuum equipped sterilizer.
Expand 1 Items
Bionova® Self-Contained Spore Ampoules for Steam (10⁶ Spores/0,25 ml)
Supplier: TERRAGENE
Self-contained spore ampoules for monitoring industrial steam sterilization of liquids. Geobacillus stearothermophilus (ATCC 7953) 10⁶ spores per ampoule (7×27 mm). 0.25 ml of culture medium. 200(+)+20(-)/BX.